Specifications

Model

UP86L-48

UP126L-48

UP1212L-48GE

AC
Input

Nominal Power

8KW

12KW

12KW

Input Voltage Waveform

Sinusoidal (utility or generator)

Nominal input Voltage

230Vac ±10%rms

Low Line  Disconnect

184Vac±4%(Normal) or 135Vac±4%(Wide)

High Line  Disconnect

 263Vac±4%(Normal) or 263Vac±4%(Wide)

Max AC input Voltage

Max 270Vac

Frequency

50Hz:41-54Hz, 60Hz:51-64Hz

AC
output

Output Voltage Waveform

Pure Sine wave

Power Factor

0.9~1.0

Nominal Output Voltage (V)

230Vac ±10%rms

Nominal Output
Frequency   (Hz)

50Hz ± 0.3Hz,  60Hz ± 0.3Hz

Solar
charger

Rated Charge Current

 60A

2*60A (120A)

PV Input Voltage range

60-145VDC

Max.PV open circuit
array voltage

145VDC   

Charger mode

MPPT

PV Low Voltage
Re-connect

PV≥Bat.V+3V

PV Low  Voltage
Disconnect

PV≦Bat.V

Efficiency

≥97%

AC
Charger

Nominal Charger
Current

7A/14A/21/28A/35A can set by user

5 stages adjustable charging current

Over charge Protection

Bat.V≥62.0VDC battery beeps 0.5s every 1s & fault after 60s

Efficiency

Efficiency(Battery Mode)

≥87%

Efficiency (Line Mode)

>98%

Battery
Voltage

Nominal DC input Voltage

48VDC

Low Battery Alarm

42VDC±1.2VDC

High DC input
Alarm & Fault

64VDC±1.2VDC

Transfer
Time

20ms(max)

System
Parameter

Over-Load Protection

110%<load<150%,beeps 0.5s every 1s,and Fault after 60s off
the output,load>150%,beeps 0.5s every 1s,and Fault after 20s

Output Short Circuit
Protection

Current limit (Fault after 10s)

Surge Rating(10s)

1:3(VA)

Power Saver

Load≤25W(Enabled on “P/S auto”Setting of Remote control)

Protections

Low battery, over charging, over load, over temp

General
Specifications

Operating Temperature
Range

0℃ to 45℃

Storage Temperature

﹣15℃~60℃

Operation humidity

5% to 95%(non-condensing)

Audible Noise

60dB max

cooling

Forced  air, variable speed  fan

Dimension(L*W*H)

627*416*204mm

Net Weight(kg)

52.5

66.5

68.5